x
I n k a r p

BWB XP Plus Flame Photometer

BWB XP Plus Flame Photometer
Distributor & Service Provider In India

Inkarp Instruments, a trusted BWB Technologies partner, introduces the BWB XP Plus Flame Photometer in India, a cutting-edge instrument for advanced elemental analysis.

Ready to use straight out of the box!
Enhanced Purpose Flame Photometer!

  • simultaneous detection and display of all 4 atoms of interest
  • “irs” (internal reference standard) caesium or lithium option
  • Intuitive user interface for True ease of use
  • Display prompts step by step operation
  • Built-in air compressor
  • Solutions and labware included
  • Data sharing via pc link via usb
  • Operator independent determination of results
  • 4 user selectable units of measure
  • User selectable decimal places
  • Integrated printer option uses readily available paper
  • Certification available: iq oq pq is completely unique in the analytical instrumentation arena. Available in english, russian, german, mandarin, french and spanish.More languages in development

    Technical Data

Sample rate 2 – 3.5ml/min
Tubing materials Silicone and Tygon®  
Required desk space for Instrument 50cm (H) x 45cm (W) x 45cm (D)*

For Safety reasons the Flame photometer requires 1m
of unobstructed space above to allow dissipation of
heat from the chimney.

Instrument size XP Plus Flame Photometer
51cm (H) x 39cm (W) x 35cm (D)
(20in x 15in x 14in)
Shipping 65cm (H) x 49cm (W) x 43cm (D)
(25in x 19in x 17in)
Weight XP Plus Flame Photometer – 14kg (30.8lbs)
Shipping – 25kg (55.1 lbs)
Optimal range Single point calibration
Na 0.1 – 60ppm
K 0.05 – 100ppm
Li 0.05 – 50ppm
Ca 1.0 – 100ppm 

Multi Point Calibration
Na 0.1 – 1000ppm
K 0.05 – 1000ppm
Li 0.05 – 1000ppm
Ca 1.0 – 1000ppm 
Reproducibility <1% Coefficient of variability for 20 consecutive samples over ten minutes at concentrations of 100ppm or less. (After instrument stabilisation).
Specificity Na/K/Li = <1% to each other when
equal in concentration at <100ppm
Limit of detection (LOD) and
limit of quantification (LOQ)
LOD
Na – 0.03ppm
K – 0.02ppm
Li – 0.02ppm
Ca – 0.3ppm
LOQ
Na – 0.1ppm
K – 0.05ppm
Li – 0.05ppm
Ca – 1ppm
Time to stability Less than 15 seconds after sample
is introduced into the flame
Ions measured Simultaneous measurement of Na, K, Li, Ca
Interfaces USB
0-2.5 volt output (based on sample concentration linked to element of users choice)
Optional 4-20mA output in place of the above
Optional integrated printer
.csv and .pdf generated reports and files via FP-PC software
Recommended minimum warm up
time based on ambient temperature
21ºC – 25 minutes
Power requirements  100V – 250V AC at 50 or 60Hz automatically selecting 
Fuel requirement   Propane, Butane or Natural Gas*
regulated to 19Bar. Flow rate of 0.4l/min
*with modifications. BWB Technologies recommends either Propane or Butane for optimum results.
Readout LCD, four line, alpha numeric, back lit.

Webinars

Upcoming Webinars

Master Polar Analyte Separation: Expert Tips for Chromatographers