Inkarp Instruments, in collaboration with Maccor, distributes the Model 4304 Battery and Cell Test Equipment in India, offering a high-precision testing solution for demanding battery R&D applications, featuring multi-channel testing, high-speed data acquisition, customizable test protocols, and advanced data analysis, supported by comprehensive sales, installation, and maintenance services, enabling Indian customers to optimize battery performance, safety, and reliability.
The flexibility of the Model 4304 allows it to be used for a wide range of applications such as Materials Research, Portable Electronic Devices, Quality Control in Manufacturing, Medical Devices, Research & Development, Battery Pack Assembly, Battery and Cell Testing, Fuel Cell Testing, Super-Capacitor Testing, Thermal Battery Testing, Qualification Testing, and much much more.
The Model 4304 test system has been engineered to provide an economical solution to meet the testing needs of research institutes, Universities, and small test laboratories. Although this system is economical in price it is rich in performance.
Number of Test Channels: | 4 independent |
Current | |
---|---|
Current Range | Per Your Specifications, currents up to 15 Amps available |
Maximum System Charge Current | Per Your Specification, up to 60 Amps |
Minimum Full Scale Current | Per Your Specifications, 150 µAmps available |
Voltage | |
Minimum Measurement | -2 Volts ‡ |
Measurement Range | Per Your Specifications, voltages up to 96 volts available |
‡ Lower minimum measurements can be attained. These would need to be discussed and agreed upon. | |
Power | |
Maximum System Charge Power | 600 Watts |
Maximum System Discharge Power | 900 Watts |
Time | |
Minimum Step Time | 5 mS* |
Control, Measurement, and Adjustment | every 5 mS |
* 4.6 mS Telecom Pulsing Feature As Standard | |
* 1.2 mS Multi-Slot Pulsing Option Available |