x
I n k a r p

CO2 Incubator with UV
Distributor & Service Provider In India((Air jacketed) BPN-50CH(UV), BPN-80CH(UV), BPN-150CH(UV), BPN-190CH(UV), BPN-240CH(UV) - (Water jacketed) BPN-30CW(UV), BPN-80CW(UV), BPN-150CW(UV))

With Infrared CO2 Sensor

Features
  • Faster CO2 concentration Restoration Speed.
  • Infrared sensor can keep CO2 concentration stability and uniformity when door open frequently.
  • Polished stainless-steel chamber, semicircular arcs at corners for easy cleaning(except water-jacketed type), and the space between the shelves in the chamber is adjustable.
  • Microorganism filter at inlet provides 99.99% filtration of bacteria and dust (Ф < 0.3μm) and supplies pure CO2 into the incubator.
  • Door temperature controller prevents dewfall on glass door of incubator effectively.
  • Independent audible and visible temperature-limiting alarm system ensures experiments run safely.(Option)
  • Alarm function for temperature difference, CO2 over concentration and concentration difference, door open time, UV working status.
  • Auto-controller of fan speed to prevent damage to the samples.
  • UV light system for periodic sterilization of chamber.
  • PID controller with LCD screen ensures precise and reliable control.
  • Two-layer stacking available.
Option
  • RS-485 Connector: easy to download and save all the data via RS-485 into computer, and identify problems in time.
  • High effective filter provides filtration of bacteria and dust.
  • CO2 pressure releasing valve
  • Humidity display system
  • Printer(Nested)
  • Temperature-limiting alarm system
  • Cooling system

    Specifications

Model BPN-50CH(UV)
BPN-80CH(UV)
BPN-150CH(UV)
BPN-190CH(UV)
BPN-240CH(UV)
BPN-30CW(UV)
BPN-80CW(UV)
BPN-150CW(UV)
Electrical Requirement 220V 50Hz
Power Consumption 450W/500W 750W 950W 250W/680W 950W
Heating Method Air-jacketed, PID Control Water-jacketed, PID Control
Temperature Range RT+5~55℃
Ambient Temperature +5~30℃
Temperature Stability ±0.2℃ ±0.1℃
CO2 Range 0~ 20% V/V
CO2 Control Resolution ±0.1%(IR sensor)
CO2 Recovery (Door open 30s,recovery to 5%) ≤ 3min
Temperature Recovery (Door open 30s,recovery to 37℃ ) ≤ 8min
Humidity Method Natural vaporization ≥ 90%
Chamber Volume 50L/80L 150L/190L 240L 26L/80L 150L
Interior Dimension(W×D×H)mm 400×350×350
400×450×500
480×530×610
520×530×690
600×630×670 290×290×310
400×400×500
500×500×650
Exterior Dimension(W×D×H)mm 580×450×540
590×657×870
670×710×950
708×710×1030
788×837×940 440×410×544
550×520×764
650×615×914
Shelves 2(pcs) 2(pcs) 3(pcs) 2(pcs) 3(pcs)